Products

Far-UVC devices for every point where contamination enters

Every UV222® device runs a filtered Ushio Care222® module at 222 nm and is designed to work with people in the room. What changes between them is where they mount, how much area they cover and how they are sealed.
In the room (7)At the cleanroom door (3)Between zones (2)On the move and in industry (3)

In the room

Fixtures that run continuously in an occupied space. The choice between them is mounting and ceiling height, not performance: the lamp is the same. A site study sets the positions and the duty cycle so the room stays inside the EU exposure limit for 222 nm.
1:11
Video · 1:11UV222 Standard
The UV222 Standard, step by step
The base lamp of the range in eight steps, from the light source to the standards it is designed to. Facts from UV Medico’s product page.
1
Krypton chloride source
A mercury-free KrCl excimer lamp, emitting at 222 nm.
2
Filtered to far-UVC
A band-pass filter concentrates the output in the 200–230 nm range.
3
60° or 100° beam
Two versions: 115 mW at 60°, 70 mW at 100°.
4
It reads the room
Motion and lidar sensors let the unit calculate its duty cycle.
5
Mounts on any surface
Walls and ceilings, or on brackets and clamps.
6
Measured, one by one
Each lamp ships with its own specifications report.
7
Built to last
Aluminium housing, quartz glass, 1.9 kg.
8
Designed to international standards
ISO 15858 · IEC 62471 · IEC PAS 63313 · ANSI/IES RP-27.1-22
UV222 Standard
UV222 Standard
The base lamp. Wall or ceiling mounted, or portable, for rooms of any type.
303.45 × 120 × 75.25 mm · 1.9 kg
max 20 W · 100–240 V AC
60° 115 mW · 100° 70 mW
0 to +50 °C · RAL 9010 matt
Datasheet (PDF) ↓
UV222 Downlight
UV222 Downlight
Recessed into a suspended ceiling where a wall lamp would be in the way.
Ø178 × 129 mm · 1.6 kg
20 W · 100–240 V AC
60° 115 mW · 100° 70 mW
Ceiling opening 150–155 mm
Datasheet (PDF) ↓
UV222 Pendant
UV222 Pendant
Suspended at adjustable height for tall spaces — atria, transit halls, waiting areas.
Ø182 × 172 mm · 2.3 kg
20 W · 100–240 V AC
60° 115 mW · 100° 70 mW
5 m nylon lead
Datasheet (PDF) ↓
UV222 Linear
UV222 Linear
Operating theatres and patient rooms. Stand-alone, or integrated directly into laminar air flow.
999 × 60 × 59 mm · 2.3 kg
max 60 W · 80–264 V AC
222 nm + white light + RGB · 115 mW
4,000 K · CRI 90 · flicker-free
Datasheet (PDF) ↓
Vertex 222
Vertex 222
Corner-mounted, covers a whole room from one point. Portable or fixed.
167 × 136.5 × 530 mm · 4.5 kg
460 mW · max 120 W · 90–264 V
IP54 · 0 to +40 °C
Aluminium, quartz glass
Datasheet (PDF) ↓
UV222 Cleanroom Downlight
UV222 Cleanroom Downlight
Flush-mounted inside the cleanroom, certified for Class A/B (ISO 5).
Ø236 × 100 mm · 1.6 kg · 20 W
IP65 — dust-tight, water jets
Inspectable primary seal, 5-year
Solid-state dehumidification
Datasheet (PDF) ↓
DUO 222 Downlight 60×60
DUO 222 Downlight 60×60
Replaces a standard 60×60 cleanroom luminaire: white light and far-UVC in one fixture.
596 × 596 × 86 mm · 8 kg
60/80/100 W · 198–264 V · IP54/65
LED 5,500–11,800 lm · 4,000 K · CRI >90
Far-UVC 115 mW · 0.486 mW/cm² at 1 m
Datasheet (PDF) ↓

At the cleanroom door

Roughly 80% of cleanroom excursions originate with the operators themselves. The Booth treats the gowned operator before entry to Grade A/B; the Wall does the same from a single panel on an existing wall; the Step-On treats the soles of their footwear — the point a sticky mat never reaches.
UV222 Booth
UV222 Booth
Decontaminates a fully gowned operator before entry to Grade A/B. Touchless.
12.0 mJ/cm² at centre in 30 s
156 sources · 3 kW · 430 kg · 230 V
1,250 × min 1,453 × 2,170 mm
Through tested PPE: <0.05% transmission
Info package (PDF) ↓
UV222 Wall
UV222 Wall
Decontaminates gowned personnel at the cleanroom entry, from a single panel on an existing wall. Touch-free.
20-second touch-free cycle
Start at 5 cm, without touching
2 kW at peak · 100–240 V AC
0 to +50 °C · 5–90% RH
Datasheet: request from us →
UV222 Step-On
UV222 Step-On
Footwear soles at entry and exit — the point sticky mats do not cover.
1,000 µW/cm² on the sole
15 mJ/cm² in 15 s · 120 W
640 × 490 × 87.5 mm · 100–240 V
IP66 · 316 stainless steel
Datasheet (PDF) ↓
1:09
Video · 1:09UV222 Booth
The UV222 Booth, step by step
A fully gowned operator walks in, turns to face a side wall and starts the cycle without touching anything. For 30 seconds, 156 filtered far-UVC sources surround the operator; when the countdown ends, the operator walks on into the classified area.
1
156 UV222 sources
Filtered 222 nm sources in a custom booth; 3 kW, 430 kg, 230 V.
2
Touchless start
A touchless operating interface with built-in safety parameters.
3
30-second cycle
12.0 mJ/cm² at the centre in 30 seconds.
4
Before entry, alongside gowning
Aids Annex 1 compliance; complementary to validated gowning and cleaning procedures.
0:52
Video · 0:52UV222 Wall
The UV222 Wall, step by step
The emitters and control system of the UV222 Booth on a single plane, mounted flat against an existing wall: no enclosure and no floor structure, so it fits facilities that are already built and running. The gowned operator stands on the floor markings and is treated in a 20-second touch-free cycle.
1
On an existing wall
No enclosure, no floor structure; every surface reachable for routine cleaning.
2
Touch-free start
A hand held over the START module for two seconds, at 5 cm.
3
20-second cycle
Filtered 222 nm far-UVC for personnel after gowning, before the classified area.
4
Status in light and sound
Ready, starting, in use, complete or fault, with no display, touchscreen or handset.
1:04
Video · 1:04UV222 Step-On
The UV222 Step-On, step by step
Recessed flush into the floor at the cleanroom entry. The operator steps on, the unit starts by itself, and the soles of both shoes are treated in under 15 seconds, on the way in and on the way out.
1
Flush in the floor
640 × 490 × 87.5 mm; IP66, 316 stainless steel, washdown compatible.
2
Starts when stepped on
Touchless activation, with nothing to press by hand.
3
Under 15 seconds
1,000 µW/cm² on the sole; 15 mJ/cm² in 15 s.
4
Where mats fall short
Covers areas sticky mats and wipes often miss and reduces reliance on them; supports Annex 1 contamination control.

Between zones

Material transfer is the other route contamination takes into a clean zone. Both units decontaminate what passes through them with light, leaving no residue and generating no particles, so ISO 14644 classification is unaffected. They reduce the need for chemical disinfection at the transfer point.
UV222 Material Airlock
UV222 Material Airlock
Walk-in transfer of materials and equipment between grades — from small tools to full vessels.
250 µW/cm² at centre
225 mJ/cm² in a 15 min cycle
Inside 150 × 120 × 80 cm
127 sources · 2.1 kW · 85–305 V
Datasheet: request from us →
UV222 Pass-Through Box
UV222 Pass-Through Box
Wall-mounted transfer of instruments and components: two modules above the load, two below it, interlocked doors and HEPA filtration.
4 × UV222 panels
~50 µW/cm² on the shelf (26–63)
Short and long cycle · max 100 W
100–240 V · stainless steel, quartz glass
Video and article → · Datasheet on request

On the move and in industry

Sealed, low-voltage and vibration-tolerant versions of the same technology, for ambulances, vehicles, food production and livestock housing.
UV222 Ambulance
UV222 Ambulance
Rear cabin of an ambulance — runs between patients, on every call, with no action from the crew.
273 × 160 × 48 mm · 1.0 kg
9–28 V DC · 20 W · IP66
60° 115 mW · 100° 70 mW
Active dehumidification · 3 m lead
Datasheet (PDF) ↓
UV222 Compact
UV222 Compact
Tight spaces: vehicle cabins, small enclosures, equipment bays.
174 × 61 × 51.9 mm · 300 g
12–36 V DC · max 5 W
60° 28.75 mW
5754 aluminium, quartz glass
Datasheet: from UV Medico shortly
UV222 Industrial
UV222 Industrial
Heavy industry, food production and livestock housing, where the fixture gets hosed down.
300 × 168 × 113 mm · 3 kg
100–240 V AC · 20 W
IP66 · IK06 · −10 to +50 °C
10 m rubber lead
Datasheet (PDF) ↓

Common to every UV222® device

Filtered Ushio Care222® lamp at 222 nm — no mercury, RoHS compliant
Lamp life ≥17,500 operating hours
Continuous, duty cycle or motion-activated
Output not user-adjustable — dose is set by distance and time
No maintenance beyond a damp cloth; no filters, no consumables
CE marked; designed to operate within the Directive 2006/25/EC and ICNIRP limits

Not sure which one your room needs?

Send floor plans and ceiling heights and we model the installation before anything is quoted — positions, fluence rate, doses and duty cycle. Free and without obligation.
Request a site study
How it works →
All specifications from the UV Medico product pages, uvmedico.com, retrieved 7 September 2026. Typical values, subject to change by the manufacturer; the datasheet governs.